Ultimate Guide of Micromotor Maintain and Repair 2023 

 

Daily Cleaning:


At the end of each day's use, the exterior of the micromotor handpiece should be cleaned to avoid the accumulation of dust and debris.
Clean the handpiece and mechanical parts to ensure no debris or residue.
Regular Inspection:

Perform a full inspection once a week to see that all parts are working properly.
Check grinding wheels for wear and replace them if needed.
Lubrication:

Regularly lubricate the moving parts of the sander according to the manufacturer's recommendations to ensure smooth operation.

 

Common Problems and Repairs for Dental Micromotor

 
Question Checklist Solution

1. Machine vibrates

Does an unbalanced grinding shaft cause it? → Are the grinding wheels worn or damaged? Replace or re-align the grinding shafts.

2. Machine overheating

- Is it caused by overuse? → Is the cooling system working properly?     Check and repair the cooling system.

3. Excessive noise    

Is the machine worn out? → Is there a lack of lubrication inside the machine?     Lubricate parts of the machine → Replace worn parts

4. The handpiece does not start or stop working  

Is the power supply connected correctly? → Are the handle buttons damaged or stuck? 
→ Is the circuit board inside the handle damaged? → Is the motor damaged?    
Make sure the power cord is securely connected. → Replace the buttons.

5. handpiece is not smooth or makes unusual noises.

Are the bearings inside the handle worn out? → Is the gear inside the handle damaged? → Is there enough lubricant in the handle? - Replace the bearings → Replace the gears → Add lubricant.

6. The machine does not start

Is there a problem with the power supply, or is the internal circuit damaged?   -Check the power cord, plug, and switch.
 Check the power cord, plug, and switch
Contact a qualified technician for repair.
 

Maintenance Precautions


USE ORIGINAL PARTS: When replacing machine parts, it is recommended to use original parts to ensure the performance and longevity of the machine.

Regular maintenance: It is recommended to carry out professional maintenance regularly to ensure the machine's optimum performance.

Avoid non-professional maintenance: If the machine malfunctions, it is recommended to contact the original manufacturer or a certified technician for maintenance to ensure safety and results.

In conclusion, proper care and maintenance can extend the life of your dental grinder and improve efficiency. We hope the above will be helpful to you!